Choosing Cellulose Cooling Pad Thickness for Polyhouses

Polyhouse Constructions Agronomy Desk · 13 ਨਵੰ 2026

A 150 mm cellulose cooling pad is usually the right choice for a commercial fan-and-pad polyhouse in India. It gives more evaporation and better cooling than a 100 mm pad, without the higher airflow resistance and design sensitivity of a thicker pad. A 100 mm pad can suit mild climates, small units or low cooling targets. Pads of 200 mm and above are for demanding hot-dry conditions and need correctly matched exhaust fans, sufficient pad area and reliable water filtration.

Do not choose thickness by summer maximum temperature alone. Evaporative cooling depends mainly on the difference between outdoor dry-bulb temperature and wet-bulb temperature. It works very well in dry summer air, but has limited effect during humid monsoon weather.

For the full system context, first understand what a fan-and-pad polyhouse is. Pad thickness is only one part of its cooling performance.

What pad thickness changes in a fan-and-pad system

A cellulose pad is a corrugated, treated-paper evaporative medium. Water flows from the top distribution pipe through the pad. Exhaust fans pull outside air through the wet channels. As water evaporates, the incoming air becomes cooler and more humid.

Increasing pad thickness generally gives air a longer path through the wet material. This can improve evaporation and cooling efficiency. But it also creates more resistance to airflow.

In practical terms, a thicker pad can:

  • improve cooling efficiency when air velocity through the pad is controlled;
  • hold more water and wet more uniformly when the distribution system is sound;
  • increase pressure drop, so fans must work against more resistance;
  • require a larger pad area or a more carefully designed fan-and-pad layout;
  • cost more material and need disciplined cleaning where water has high mineral content.

A thick pad does not automatically make the crop zone cooler. If fan capacity is inadequate, the pad area is too small, outside air is humid, or hot air leaks into the structure, the expected benefit will not appear.

Also remember that a cooling pad adds moisture. In rainy weather or already humid coastal conditions, run-time and fan staging must be managed carefully to avoid excessive relative humidity, condensation and disease pressure.

100 mm, 150 mm and thicker pads: a practical comparison

The following ranges are broad design guidance. Actual saturation efficiency depends on pad flute design, face velocity, uniform wetting, cleanliness, fan static pressure and air leakage around the pad.

Pad thickness

Typical use case

Indicative cooling efficiency potential*

Main advantage

Main limitation

100 mm

Mild to moderate heat load; small or lower-cost systems

About 65–75%

Lower resistance to airflow; simpler, lower material use

Lower cooling potential in harsh summer conditions

150 mm

Most commercial vegetable and flower fan-and-pad polyhouses

About 75–85%

Strong balance of cooling, airflow and practical pad area

Still needs good water treatment and fan matching

200 mm or thicker

Very hot-dry locations or high cooling requirement

About 80–90% under suitable conditions

Can achieve higher evaporation efficiency

Higher pressure drop; not suitable as a simple upgrade without redesign

*Efficiency is the share of the available dry-bulb-to-wet-bulb temperature difference achieved by the pad. It is not a guaranteed temperature reduction.

For example, if outdoor air is 40°C dry bulb and 25°C wet bulb, the theoretical maximum evaporative cooling difference is 15°C. At 80% pad efficiency, air leaving the pad may be roughly 12°C cooler, or near 28°C. Heat gain from the roof, crop, motors and incoming leaks can raise the temperature further by the time air reaches the fan end.

If outdoor air is 34°C dry bulb and 29°C wet bulb during humid weather, the available difference is only 5°C. Even an excellent thick pad cannot produce dry-season cooling in that condition.

When a 100 mm cellulose cooling pad makes sense

A 100 mm pad is not automatically a poor choice. It can be sensible where the cooling target is modest and the system is designed around it.

Choose or retain 100 mm pads when most of these points apply:

  • Your location has relatively moderate summer afternoons or shorter severe-heat periods.
  • The crop can tolerate some variation in afternoon temperature.
  • The structure is small and the objective is heat relief rather than precise climate control.
  • You have adequate pad face area and do not plan to force excessive airflow through a small wall.
  • Water has mineral issues and you want a thinner medium that is easier to inspect and replace, while still improving filtration.
  • Capital budget is limited, but fan-and-pad cooling is still needed.

A 100 mm pad may also be used in regions where humid weather dominates. The reason is not that humidity improves pad cooling; it does the opposite. Rather, spending on a thicker pad may bring little extra cooling where the wet-bulb temperature stays high for much of the season.

However, do not use a thin pad simply to compensate for undersized fans or a poorly planned pad wall. That approach can create fast air movement at the pad with incomplete evaporation, uneven cooling and hot spots deeper inside the polyhouse.

Why 150 mm is the default for many Indian polyhouses

For crops such as capsicum, cucumber, tomato, gerbera and similar high-value protected crops, the summer cooling system must operate for long daily hours. In many inland areas, 150 mm pads offer the most practical compromise.

They provide enough wetted depth to capture much of the available evaporative cooling potential in dry heat. At the same time, the airflow penalty remains manageable if the pad wall is correctly sized and the exhaust fans are selected for the system resistance.

A 150 mm pad is particularly suitable when:

  • summer conditions are hot and dry to moderately dry;
  • crop quality and yield depend on limiting peak afternoon stress;
  • the house is long enough that temperature rise from pad end to fan end matters;
  • you are installing a purpose-built fan-and-pad system, not adding cooling later;
  • the farm can maintain filtration, sump cleaning and uniform water distribution.

This thickness is also widely available in standard modules. For example, cellulose pad material can be planned alongside the frame, gutter, pump and distribution arrangement. The module size is not a reason by itself to select 150 mm, but standardised sizes can simplify wall layout and future replacement.

Before finalising, calculate airflow first and then match the total pad face area to that airflow. Read how to match cooling pad area with exhaust fans before deciding the length and height of the pad wall.

When 200 mm or thicker pads are worth considering

A 200 mm or thicker cellulose pad is a specialist choice. It can make sense in very hot, dry interiors where the difference between dry-bulb and wet-bulb temperature is large and the crop has a strict heat-management requirement.

Possible situations include long, severe summers in dry parts of central, western or northern India. Site data matters more than the state name. Two farms in the same district can differ because of altitude, nearby irrigation, local wind and the timing of humidity rise.

Consider a thicker pad only if all of the following are true:

  1. Your climate has usable evaporative potential. Check afternoon dry-bulb and wet-bulb readings for the hottest months, not just the maximum temperature reported in a weather app.
  2. You need more cooling than a properly sized 150 mm system can reasonably provide. This should be based on crop response and climate data, not an assumption that thicker is always better.
  3. Pad face area is adequate. Do not reduce wall area just because the pad is thicker.
  4. Exhaust fans can deliver the intended air volume at the expected static pressure. Fan catalogue airflow at zero pressure is not enough for final design.
  5. Water quality and maintenance capacity are strong. A thick pad that develops scale, algae or dry strips will lose its theoretical advantage.
  6. The structure is reasonably airtight on the intake side. Open gaps, damaged curtains and bypass openings let hot air enter without passing through the wet pad.

A thick pad with unsuitable fans can reduce total airflow. The crop may then experience slow air exchange and uneven temperature from one end of the house to the other. Review how to calculate exhaust fan size for fan-and-pad polyhouses as part of the design.

Use climate and crop need, not only the thermometer

The best pad thickness comes from a cooling-load decision, not a single temperature number. Use the hottest critical period for your crop. For many farms, this is the afternoon period from March to June; in some regions, dry pre-monsoon heat is more important than the absolute maximum temperature.

Hot and dry inland conditions

In dry air, pads can deliver meaningful cooling because evaporation is high. A 150 mm pad is usually the starting choice. A 200 mm pad may be justified for highly heat-sensitive crops, longer houses or demanding temperature targets, provided the fans and pad area are designed together.

Hot and humid coastal or monsoon conditions

When humidity is high, the wet-bulb temperature is close to air temperature. Pad cooling reduces sharply, regardless of thickness. In such locations, prioritise adequate ventilation, roof shading where appropriate, air circulation and crop humidity management. A 100 mm or 150 mm pad may be adequate, but a thicker pad often gives limited return.

Moderate plateau or winter production conditions

Where severe summer operation is limited, 100 mm may be sufficient. If the same polyhouse will grow a high-value summer crop, a 150 mm design offers more operating flexibility.

Crop sensitivity

Young transplants, leafy greens and some flowers can suffer quickly under heat stress. Fruiting vegetables also lose fruit set and quality at high temperatures. Yet cooling targets differ by crop stage, variety, plant load, radiation and market window. Discuss target temperature and humidity ranges with your crop adviser rather than selecting pad thickness from a generic crop list.

Water quality can decide whether the pad performs for years

Hard water, high alkalinity, suspended solids, iron and biological growth do not usually dictate pad thickness alone. They do determine whether any pad thickness remains effective.

Mineral deposits block the pad channels. Algae reduce wetting and restrict airflow. Uneven water distribution leaves dry bands that allow warm air to pass through. A 200 mm pad may be more difficult and expensive to maintain if source water is poor, because it has more wetted media and greater pressure sensitivity.

Before installation, test the source water for:

  • total dissolved solids (TDS);
  • hardness and alkalinity;
  • pH;
  • suspended dirt or silt;
  • iron, where borewell water is known to contain it;
  • seasonal changes in water quality.

Use suitable filtration and plan a bleed-off or drain-and-refill routine to prevent minerals from concentrating in the sump. The exact treatment depends on the lab report and source water. Avoid guessing chemical treatment; take advice from a water-treatment provider, KVK or protected-cultivation agronomist.

For ongoing work, follow a written cellulose cooling pad maintenance schedule. It should cover filter cleaning, water distribution checks, sump cleaning, pump inspection and off-season drying. Good maintenance can matter more than moving from 150 mm to 200 mm.

A selection checklist before ordering pads

Use this checklist with your fabricator, climate designer or agronomist.

  1. Record local peak conditions. Take dry-bulb temperature and relative humidity readings at the farm during hot afternoons. Convert these to wet-bulb temperature or use a reliable psychrometric tool.
  2. Set the crop requirement. Define the acceptable daytime temperature range and the maximum humidity you can tolerate at the crop stage.
  3. Estimate the achievable cooling. Start from the dry-bulb-to-wet-bulb difference, then apply a conservative pad efficiency range.
  4. Select a preliminary thickness. Use 100 mm for modest demand, 150 mm for most commercial systems and 200 mm-plus only for verified high-demand dry-climate designs.
  5. Size pad area and fans together. Confirm air velocity through the pad and fan performance at operating static pressure. Do not finalise one component independently.
  6. Check water quality and treatment. Budget for filtration, a clean sump, drain points and access for maintenance.
  7. Plan the physical installation. Provide a rigid frame, bottom gutter, top distribution pipe, pump access, return line and sealing around the pad wall.
  8. Plan power-failure protection. In peak heat, crop damage can happen quickly when fans and pumps stop. Keep alarm, generator or other backup arrangements suited to the farm’s risk.

For material planning, Polyhouse Constructions lists individual protected-cultivation components and complete material kits. You can build a kit and check current item quantities and weekly rates rather than relying on an old price list.

Common thickness-selection mistakes

The most common mistake is treating a cooling pad as an independent purchase. A pad, exhaust fan, pump, plumbing, controller, shade strategy and sealing arrangement must work as one system.

Avoid these errors:

  • Choosing 200 mm pads because the outside temperature reaches 40°C, without checking wet-bulb temperature.
  • Using 100 mm pads on a large, hot house while expecting flower-grade climate control.
  • Installing a small pad wall and pushing too much fan airflow through it.
  • Selecting fans by nominal diameter or free-air rating rather than airflow at pressure.
  • Running pad water continuously in humid weather, causing excessive humidity and plant disease risk.
  • Ignoring filtration because the water looks clear.
  • Allowing water to bypass, drip unevenly or leave dry patches on the pad.
  • Failing to close gaps around the cooling wall and doors while the system is operating.

Next steps

Start with climate readings from your own farm during the hottest weeks. If the site is hot and dry, assess a 150 mm pad system first and move to thicker pads only when calculations show a clear benefit. If the site is hot and humid, focus equally on ventilation, humidity control and shading rather than expecting a thick pad to solve summer heat.

Then finalise the exhaust-fan airflow, total cooling-pad face area, pad thickness, water filtration and backup-power plan as one package. This gives a more reliable result than upgrading pad thickness after the polyhouse is already operating.

Frequently asked questions

Can I replace a 100 mm cooling pad with a 150 mm pad in an existing polyhouse?

Usually yes, if the frame, gutter and water-distribution arrangement can accept the extra thickness. But first check whether the existing exhaust fans can maintain the required airflow against the additional resistance; otherwise cooling may not improve as expected.

Will a 200 mm cellulose pad reduce polyhouse temperature by 10°C?

It may achieve a large temperature drop in very dry air, but no thickness can cool below the outdoor wet-bulb temperature. The actual crop-zone temperature also depends on solar load, fan airflow, pad area, air leaks and house length.

Which pad thickness is best for a polyhouse in Maharashtra?

There is no single Maharashtra answer because dry heat and humidity differ across districts and seasons. A 150 mm pad is often a sensible commercial starting point in hot inland locations, but confirm it using local afternoon temperature and humidity readings.

Does hard borewell water require a thicker or thinner cooling pad?

Hard water mainly calls for better filtration, sump management and scale control rather than a particular thickness. If water quality is poor and treatment is not reliable, a very thick pad can become difficult to keep uniformly wet and clean.

How long does a cellulose cooling pad last?

Life varies with water hardness, operating hours, cleaning, sunlight exposure and whether the pad is dried properly in the off-season. Replace it when scale, collapse, permanent blocked channels or uneven wetting prevent normal airflow and cooling, not only because of its age.