How it worksBuy individual items

How to Clean Polyhouse Cooling Pads Without Damaging Cellulose

Polyhouse Constructions Agronomy Desk · 13 Nov 2026

A dirty cooling pad gives less cooling just when the crop needs it most. Algae makes the pad slimy, mineral scale closes the flute channels, and dust blocks airflow. The safe method is to isolate the fan-and-pad system, remove loose dirt with a gentle rinse, clean the tank and distribution pipe, then use only a cellulose-pad-compatible descaler for stubborn scale.

Do not use a pressure washer, hard brush, wire, strong acid, strong alkali or chlorine bleach on cellulose pads. These can break down the treated paper, widen or collapse the channels, and shorten pad life.

Know whether it is algae, scale or a water-flow problem

First identify what is on the pad. The visible symptom may look similar, but the correction is different.

What you see

Likely cause

Safe first action

What not to do

Green, brown or black slippery film

Algae and biofilm from sunlight, warm water and nutrients

Drain, rinse gently and clean the tank, screens and pipe

Scrub hard or add an unapproved disinfectant

White, grey or yellow crust

Calcium, magnesium or iron deposits in hard water

Use a pad-compatible descaler as per its label, then rinse well

Use strong acid or leave descaler in the pad for long

Dry strips or bands on the pad

Blocked top pipe holes, uneven levelling or weak pump flow

Clean distribution holes and check pad level

Assume the full pad needs chemical cleaning

Dusty face and poor air movement

Wind-borne dust, chaff or clogged inlet screen

Vacuum lightly or rinse at low pressure

Direct a high-pressure jet into the pad

Sections that stay wet after shut-off

Poor gutter drainage, damaged frame or sagging pad

Clear the gutter and correct the slope

Continue running the pad until the cause is fixed

Algae normally starts in the sump, recirculation line or shaded wet parts of the pad. Scale normally begins at the top where water first enters, then spreads down the water channels. If only a few vertical strips are dry, inspect the water-distribution system before treating the entire pad.

For the basics of the system, see what a fan-and-pad polyhouse is. Pad cleaning will not correct an undersized pad or incorrectly matched exhaust system; review how cooling pad area should match exhaust fans if cooling has always been uneven.

Prepare safely before cleaning

Choose a relatively cool morning, late afternoon or a non-critical crop period. Do not take the cooling system offline at peak afternoon temperature when the crop depends on it. In hot districts, plan the job in sections if the pad wall is long.

Tools and supplies

Keep these ready:

  • Clean water source and a low-pressure hose with a broad spray pattern
  • Soft nylon brush or soft cloth for the frame, gutter and tank only
  • Plastic bucket, scoop and a soft plastic scraper for the sump
  • Gloves, eye protection and non-slip footwear
  • A torch for inspecting the back of the pad and distribution pipe
  • A pad-compatible descaler, only if mineral crust remains after rinsing
  • pH strips or a meter if you use a descaler and need to verify complete rinsing
  • Replacement filters or screens if they are torn or permanently clogged

Check the pad maker's instructions before using any cleaner. Cellulose cooling pads are specially treated paper media. A cleaner that is acceptable for plastic pipes or a concrete tank may not be safe for the pad itself.

Isolate electricity and protect the crop

  1. Switch off exhaust fans, circulation fans, pump and automatic controller output for the pad pump.
  2. Isolate the electrical supply at the proper isolator. Lock or mark it so that nobody restarts the system during work.
  3. Open vents, curtains or doors as the weather allows. Keep crop workers out of the wet work area.
  4. Place tools away from electrical panels and fan motors. Do not spray water near motors, switches or control boxes.
  5. If you are cleaning the sump with an approved product, prevent wash water from entering irrigation tanks, fertiliser stock tanks or a farm pond.

Never mix cleaning chemicals. In particular, do not combine acidic descalers with chlorine-containing products. Dangerous fumes can result.

Step-by-step: how to clean polyhouse cooling pads

This method is suitable for routine cleaning and light-to-moderate deposits. For pads that are brittle, crushed, badly sagged or heavily scaled throughout, replacement may be more practical than aggressive cleaning.

1. Drain and inspect the whole water circuit

Drain the sump or tank completely. Scoop out leaves, algae lumps, sand and settled scale. Remove and wash the pump inlet screen, filter screen and any strainer according to their design.

Inspect the following before touching the pad face:

  • Sump walls and bottom for slime or sediment
  • Pump impeller area and inlet screen
  • Filter housing and screen
  • Supply line joints and valves
  • Top distribution pipe or trough
  • Holes, slots or nozzles that spread water across the pad
  • Bottom gutter and drain line

A clean pad will become dirty again quickly if the sump holds nutrient-rich sludge. If fertigation backflow or contaminated source water is entering the pad circuit, correct that issue first.

2. Remove dry dust gently

When the pad is drained and not dripping, remove loose dust from the air-entry face with a vacuum using a soft brush attachment, or with a very gentle broad water spray. Work from top to bottom.

Keep the nozzle at a distance and use only enough force to move dust. Do not force the spray into the flute openings. High pressure tears the paper edges and drives debris deeper into the channels.

Do not use a stiff brush on the pad surface. A soft brush is useful for the metal frame, top pipe and gutter, not for scrubbing cellulose media.

3. Flush the distribution pipe and clear dry channels

Remove the end cap or open the flushing point of the top distribution pipe if the design permits. Flush it with clean water into a bucket or drain until sediment stops coming out. Clean individual holes or slots gently using a soft plastic pick or the method recommended for the pipe.

Do not push wire, nails or sharp tools into the pad channels. If a channel looks blocked, first restore even flow from the top pipe. Then run clean water through the pad for a short period and observe whether the dry strip disappears.

The pad should wet evenly across its full width within a few minutes of pump operation. Persistent dry bands may indicate a pad that is not level, a distorted distribution trough, low pump flow or internal mineral blockage.

4. Rinse algae from the pad and clean the sump separately

Use low-pressure clean water from the top so that water follows the normal downward route. Let it drain freely from the bottom gutter. Repeat until loose algae, dust and fine sediment stop appearing in the runoff.

For algae in the tank, pipe and gutter, physically remove slime first. Wash the empty tank, then rinse it thoroughly. If sanitation treatment is needed, use only a product approved for your pad system and follow its label, including contact time and complete rinsing. Ask your KVK, agronomist or equipment supplier if you are unsure of compatibility.

Do not try to solve algae by continuously adding a random chemical to recirculating water. It can damage the media, affect workers and crops, and hide the real cause: sunlight, dirty water or poor bleed-off.

5. Treat mineral scale only where necessary

If a white or hard crust remains after plain-water rinsing, use a descaler specifically stated to be compatible with cellulose evaporative cooling pads. Follow the product label exactly for dilution, application method, contact time and safety gear.

Apply the treatment evenly and only to the affected pad area where possible. Do not soak the pad longer than directed. Keep it off fan motors, electrical parts, crop foliage and unprotected metal components. After treatment, rinse from top to bottom with plenty of clean water until there is no cleaner residue in the runoff. Check pH if your procedure calls for it.

Avoid household toilet cleaners, battery acid, brick-cleaning acid, caustic soda, bleach and unverified homemade mixes. They may remove deposits quickly, but they can weaken cellulose, corrode components and create a crop or worker safety risk.

6. Reassemble and run a water-distribution test

Clean the filter and strainer, reinstall them, and fill the sump with clean water. Run the pump without starting the exhaust fans first. Stand on both sides of the pad wall and look for:

  • Full-width wetting at the top
  • No dry vertical strips
  • No overflow from the top trough
  • Free drainage into the bottom gutter
  • No leaks at pipes or joints
  • Clean, even runoff rather than dirty or foamy water

Then run fans and pads together for a short test. Air should pass freely through the whole pad. If one bay still has poor cooling or visibly weak airflow, inspect for a crushed pad section, blocked frame opening or fan-side airflow problem. The cellulose pad maintenance schedule can help set up checks between deep cleans.

How to deal with blocked pad channels without damaging them

Blocked channels are the most tempting place to use force, and that is where many pads get damaged. The corrugated paper structure must remain open and straight for both water and air to travel through it.

Use this order of action:

  1. Check water distribution first. Clean the top trough and distribution holes. A blocked hole can create a dry stripe that looks like an internally blocked pad.
  2. Flush in the normal direction. Use clean, low-pressure water from the top. Allow the gutter to drain freely.
  3. Remove external debris only. Lift leaves or insects from the surface with fingers or a soft cloth. Do not insert any tool into the channels.
  4. Use approved descaling only for confirmed hard-water deposits. Test a small, less critical section first if the product instructions allow it.
  5. Replace damaged sections. A crushed, delaminated or permanently sealed pad section will not regain its original airflow through repeated washing.

Cellulose pads are available in different thicknesses and flute configurations. Thickness affects resistance to airflow, water holding and cooling performance, so replace like-for-like unless your designer recommends a system change. Read how to choose cellulose cooling pad thickness before changing the pad specification.

Stop algae and scale from coming back

Cleaning is only half the job. Prevention reduces water use, labour and crop heat stress during summer.

Manage water quality and concentration

Hard borewell water commonly leaves calcium and magnesium deposits. Water with iron can leave brown staining, while dirty storage tanks add sediment. Have the source water checked when scale keeps returning quickly. The required filtration and treatment depend on water quality, pad system size and local conditions.

Use a suitable filter before water enters the pad circuit. Clean its screen on schedule. Maintain a regular bleed-off or partial drain-and-refill practice so dissolved salts do not become more concentrated as water evaporates. The right frequency varies with source-water EC, hardness, temperature and daily operating hours.

For a broader system check, see water filtration needed for foggers and cooling pads.

Limit sunlight, sediment and standing water

Algae needs light, water and nutrients. Cover or shade the sump where safely possible, keep the lid in place, and stop leaves, soil and fertiliser water from entering it. Ensure the bottom gutter has a proper slope and does not retain stagnant water after the pump stops.

At the end of the daily cooling period, allow pads to drain. In humid weather, do not run pads when ventilation alone can maintain acceptable crop conditions. Constantly wet pads increase algae risk and can also raise inside humidity.

Cleaning frequency and warning signs

The best interval differs across India. A fan-and-pad polyhouse in dry, dusty summer conditions may need frequent filter and sump checks. A unit using hard borewell water may need earlier scale inspection. During monsoon, algae risk may increase where water stands and sunlight reaches the sump.

Use this practical schedule as a starting point:

Task

Suggested timing

Increase frequency when

Check pad wetting and dry bands

Daily during active cooling

Temperature is high or pump runs for long hours

Clean filter, strainer and visible debris

Weekly or as flow reduces

Water is dusty, tank is open or borewell water carries sediment

Drain and clean sump and gutter

Every 2–4 weeks in regular use

Algae, smell, slime or sediment appears sooner

Inspect for scale and pad softness

Monthly

Water is hard or deposits appear at the top edge

Deep clean and inspect all parts

Before peak summer and after the main season

The system has been idle or performance has dropped

Replace rather than clean if the pad has extensive tears, soft pulpy areas, collapsed flutes, delamination, mouldy odour that remains after cleaning, or persistent airflow restriction. Repeated chemical cleaning is usually a sign that source-water management needs improvement. If replacement is required, compare suitable cellulose cooling pad material specifications with your existing system.

Next steps

Inspect one pad bay, the top distribution pipe and the sump before the next hot spell. Start with gentle mechanical cleaning and restore even water flow. Use a compatible descaler only for confirmed scale, and correct the water-quality or drainage cause so the problem does not return.

If you are reviewing pad media, filters or other fan-and-pad materials, you can view individual protected-cultivation materials or build a material list with current item quantities through the online kit builder.

Frequently asked questions

Can I wash cellulose cooling pads with a pressure washer?

No. A pressure washer can tear the treated paper, crush the flute structure and push dirt further inside the channels. Use a low-pressure, broad water spray and keep the nozzle away from the pad face.

Can I use bleach to remove algae from cooling pads?

Do not use bleach unless the cooling-pad manufacturer specifically approves a product and procedure for that media. Chlorine products can damage cellulose and must never be mixed with acidic descalers.

Why does my cooling pad have white deposits at the top?

White deposits are usually mineral scale from hard water, often calcium or magnesium salts. Clean the distribution pipe first, then use a cellulose-pad-compatible descaler only if rinsing does not remove the crust.

How do I know whether the cooling pad is blocked or the pump flow is low?

Run the pump with fans off and observe the top of the pad. Dry vertical stripes usually point to blocked distribution holes, poor levelling or low flow, while widespread poor wetting may indicate a dirty filter, pump issue or internal deposits.

Should cooling pads be kept wet all day in summer?

Pads should run when cooling is required, based on inside temperature and humidity, but they should not stay wet unnecessarily. Allowing them to drain after operation reduces standing water, algae growth and excess humidity.